MJSE's thread: RSNetworx and 1769-SDN DeviceNet module ()

#Can rslinx classic lite recognize compactlogix update#

There is also important info posted there regarding a patch that allows users to continue to use RSNetWorx v10.01/v11 with the newer EDS Subsystem, saving users from having to update to v21, if they wish not to. I have only just similarly replied to MJSE in that other thread explaining a possible reason for their problem. I noticed this thread as MJSE had just posted here this morning seeking help with their issues from another thread they had started recently. This is why, in most cases, updating RSNetWorx to v21 fixed the issue, as v21 is compatible with the newer EDS Database. RSNetWorx v10/v11 uses the older EDS file system of registering EDS files in Windows Registry, and so can no longer access the required EDS files through the Registry. Even though they may appear to be registering correctly, they are being registered to the new Database.

#Can rslinx classic lite recognize compactlogix software#

Once one of these products is installed, the entire PC is updated the to the newer Database, the older software products can no longer access EDS files correctly. If RSLinx Classic was not the culprit, then perhaps one of the other possible products which updates the EDS Subsystem to the newer SQL Database? Not all posters who have had issues have stated which version of RSLinx Classic they were using at the time that RSNetWorx v10/v11 would not work correctly, but I would hazard a guess that they had RSLinx Classic v3.51 or above installed at the time. I had not read this thread when it was originally posted. something to do with DLL getting messed up.ĭon't have exact details, but you will have to search Rockwell Knowledge base, hopefully a fix is there now as the current method to fix involves removing all software and re-installing. Two of us on our office were just bit by this bug. RSLinx can see both devices on the DeviceNet through the EthernetIP connection to the CompactLogix as well as the 3 flex IO devices connected the Flex IO Adapter Any attempt to change properties on the device brings up a prompt saying the device isn't registered and asks if I want to run the EDS wizard again.

#Can rslinx classic lite recognize compactlogix registration#

The registration completes (with no errors for the 1769-SDN but one for the 1794-ADN) but a question mark still remains over the devices, with a message in the message windows saying "The device at address XX is not registered on this computer".

#Can rslinx classic lite recognize compactlogix download#

I right click on each device then go to register each device by downloading the EDS using the download link in the Wizard. Upload is skipped because the devices have not been registered. RSNetWorx finds 1769-SDN Scanner Module at address -ADN Flex I/O Adapter at address 01. I Open up RSNetWorx click Online and browse for the devices on the network after I have selected my communications. I am unable to register Devices in RSNetWorx. I am a long time reader/first time poster on the site and am hoping someone can help me with a problem I am having with my DeviceNet Setup.